• SAMPLE

    Please see the download attachments for sample Job Drawings and Photos.

    These are modular units with horizontal cross bus

    Enclosures are NEMA 3R aluminum construction

    EQUIPMENT MUST BE CONFIGURED TO
    SPECIFIC UTILITY METERING REQUIREMENTS
    (CONSULT FACTORY FOR SPECIFIC APPLICATIONS)

    Equipment must be quoted and purchased through an Electrical Distributor
    For Pricing information see download "RFQ form"

  • 480Y/277 Volts Termination Boxes

    • Main Termination Box 400-2000A
    • Main Switch Top Feed 400-800A
    • Main Switch Bottom Feed 400-800A
    • Type VL & VLB Main Switch 800-2000A
    • Main Circuit Breaker 400-800A


    For Product Specs and Catalog Numbers see Download Attachments.
    For Pricing information see download "RFQ form"

  • Hot Sequence

    • Hot Sequence Meter Stack (meter ahead of disconnect)
    • Cold Sequence Meter Stack (disconnect ahead of meter)
    • Dual Disconnect Meter Stack (non-fused disconnect ahead of meter, fused disconnect after meter)

    *** Type of configuration depends on utility requirement ***


    Must be used in conjunction with a main device ahead
     

    For Product Specs and Catalog Numbers see Download Attachments.
    For Pricing information see download "RFQ form"

  • 400, 600 and 800 Amp. Combination Current Transformer Section and Disconnect (Disconnect at Bottom)

    • CT Section at Top, Disconnect at Bottom 400-800A (CTA)
    • CT Section at Bottom, Disconnect at Top 400-800A (CTB)
    • Disconnect can be Fused Pullout, Fused Switch or Circuit Breaker
    • 400A Pullout load lugs will accept 500MCM max


    Must be used in conjunction with a main device ahead

    Above 800A must use "CTSS" (Stand-alone configuration)
     

    For Product Specs and Catalog Numbers see Download Attachments.
    For Pricing information see download "RFQ form"

  • 480Y/277V Bussed Spacer

    • Provides required clearance distance between cabinets.
    • Spacer: 4" - 8" - 12" sizes available.
    • Corner Elbow: Provides required clearance distance around inside corners between cabinets.

     

    For Product Specs and Catalog Numbers see Download Attachments.
    For Pricing information see download "RFQ form"

  • Single Meter Disconnect

    SMP Unit - Single meter / Disconnect
    Disconnect can be either fused pullout or circuit breaker
    Line lugs at Top - Line MUST be fed from the top - No internal wireway

    CM0 Unit - 2 - 3 meter positions
    Type CM0T - Main lugs at Top
    Type CM0B - Main lugs at Bottom
    Disconnects can be either fused pullouts or circuit breakers

    For Product Specs and Catalog Numbers see Download Attachments.
    For Pricing information see download "RFQ form"